Prius (Gen 3) :: Blower Motor Not Working After Replacement


Jul 17, 2016

Several weeks ago, the blower motor in my 2010 stopped blowing. It came on within a day or so, but failed again, so I replaced it with a new part from Rock Auto: TYC 700249.

​The new fan just stopped again. I plugged the harness in and out several times and it did briefly come on a few times, but clearly something else is going on.

I don't know if it's relevant, but after I took out the OEM fan, I experimented by removing the plate from its back that has wires and capacitors (actually, I don't know what I'm talking about) and connected the main prongs directly to a 12V battery. It came on right away. I installed the new fan anyway, figuring it was the plate/wires assembly portion that was bad. The "resistor?"

View 7 Replies

Advertisement

Civic - Honda :: 2003 - Fan / Blower Motor Not Working After Rotor Replacement And Oil Change

Our 03 Civic recently went into the shop for a rotor replacement and the shop did an oil change for us while they were at it. My wife got the car back and she immediately noticed that the "AC" wasn't working. After asking a few additional questions (I'm not in the same city this week), it isn't the AC that isn't working, the fan/blower isn't turning on at all. We had the same shop check it out again and their response was that they weren't anywhere near the blower motor so this just has to be a coincidence. I could accept that but I'm still worried about a scam.

The car was in the shop just to have the rotors put on, not an oil change but they did an oil change for us anyway. (I was going to change the rotors myself but I couldn't get the caliper hangers off and it was 100+ degrees outside so I decided to have the shop mess with it), Would it be easy to sabotage the blower motor on this car?

View 6 Replies

Prius (Gen 1) :: Blower Motor Replacement / Way To Get It Under Glove Box?

How to replace blower motor in 01 Prius. There are no way to get from to it from under the glove box.

Blower motor was working fine. I decided to remove cabin filter. Filter had not been changed for very long time. There was a lot of dirt, pine straw and leaves on top of the filter. When I removed the filter a lot of dirt fell inside the motor. Ever since then motor is working on and off. Often have to hit under the glove box and it works again for a while. Tried to remove the blower but could not get to it.

View 14 Replies

Prius (2004-09) :: 2006 - HVAC Blower Motor Replacement?

I am struggling with it, and need to get it done - by myself, as I can't afford a service job. I am handy, and comfortable doing it, But I am confused about how to get into the blower housing.

View 4 Replies

Santa FE SM (2001-06) :: AC / Heater Blower Motor Replacement

How hard is it to change the A/C/Heater blower motor. I know about the switch problems but this is the blower motor. I'll probably clean it out and spray something in it before I replace it but I just wondered how hard it is to get to. On another note, this 4 wheel drive Santa Fe rocks in the snow! I can't believe what good traction it has!

View 3 Replies

Taurus :: Blower Motor Completely Quit Working

My a/c has not been working so we added R134a yesterday and it fixed the problem just like it did last summer. Once I was finished I left the a/c on high when I shut my car off. This morning when I left for work it was too cold so I turned it to the "off" position. On my drive I decided to turn the a/c on and make sure it was still getting cold at which point nothing happened, absolutely no air (hot or cold) was blowing out. I kept turning it on and off and at one point the a/c did start working again at which point I turned the fan speed to low. A few minutes later the blower completely quit working again. Nothing works at any speed, any position regardless of heat or a/c. Absolutely nothing is blowing out of my vents. I can hear something that sounds like opening and closing when I change the position/type of a/c/heat but the other than that the only sound is a "shhhhhhh" when I turn it to the off position. Where to start on diagnosing and fixing this issue?

View 14 Replies

Accent RB (2012+) :: AC Blower Motor Stopped Working

Turning the fan knob yields no results. The AC compressor does kick in as I can feel it when I turn it on when idling, so the knob appears to work. The blower does not move air.

I checked the fuse below the steering wheel and the fuse makes a complete circuit although the edge looks a bit darkened. Other fuses from working devices look the same and I took a spare 10A fuse from the designated area and inserted into the blower motor fuse location - still nothing.

I will also inspect the relays/fuses in the engine compartment to see if anything in there looks blown that's related to the blower motor. Hopefully it will be something simple, but probably not...

I will need to take it in to get it looked at and fixed, and this is probably not under warranty since vehicle has 56k miles... while I'm there I'll have a transmission fluid exchange done as well and I was planning on getting some body work done.

My bumper was torn off from the fact that it sits low enough that sometimes it would go over the parking stump. Well, it eventually got caught really bad and tore it off. Now the tab where the screw goes to secure the bumper has sheared off so it just hangs. Also, the tearing action from the parking stump caused the inner fender to come off and rub against my tire while driving, tearing it into shreds from the friction.

View 7 Replies

Golf IV / Jetta IV :: Heater Blower Motor Not Working

I got a new resistor since my last one was in a puddle of water and installed that today and still have no heater blower motor. I checked all the fuses and have power. I sent power to the blower itself and it spins good. So somewhere between the fuse and the blower it isn't working. I need to take the controls out and test for power there. Didn't have time to do that today. What wires to check or where to start trouble shooting?

View 7 Replies

Golf IV / Jetta IV :: 2008 - Blower Motor Not Working?

Blower motor has stopped working on my 2008 jetta 2.0. Motor works fine and I have traced the issue back to the fan switch connector which is not getting power. Seems like it should be a fuse issue, but they all seem to check out fine. Not sure where else to look. Is there a relay upstream that could be bad? I have owned since new and it has never been apart.

View 3 Replies

Ford A/C :: Blower Motor Stopped Working - No Power

I have a Full Size 93, 5.8L Van. The blower motor has stopped working. I have checked the fuzes, ok. I have checked the Power Distrubution Box, ok. I do have power to my Aux (rear) blower. I have hot wired my blower motor, it works. I have no power to the blower motor, thermal limiter, or to the fan control switch on the dash. (Like I said, the Aux on the dash works). What else is there?

View 14 Replies

LeSabre :: 2004 Replaced Blower Motor - Heat Isn't Working

A few weeks ago my battery died and I had to jump start my car. After the jump start, my heat wasn't working - no air will blow out on heat or A/C. I checked the fuses - all good.

I pulled the blower motor out and tested it and it worked hooked up to a battery. At one point when the blower motor was still in the car I banged it with a hammer and it turned on momentarily then shut off again.

Since the blower motor seemed to work outside of the car, I assumed it was the resistor that was bad. Replaced , and still no heat.

Could the blower motor be bad and just have worked hooked to a battery intermittently?

What else could it be?

View 1 Replies

Suburban :: Front Blower Motor Stopped Working On All Speeds

I own a 99 Suburban 1500 5.7. The front blower motor stopped working on all speeds so I replaced the resistor, it still did not work. I then replaced the speed selector switch and it started working fine. Three days later I smelled a slight electrical burning smell and the fan stopped working again. I plan on replacing the switch again to see if that is what went bad. Whats causing this to happen? Maybe the motor is going bad and causing the switch to short?

View 6 Replies

Golf IV / Jetta IV :: 2000 TDI Blower Motor Stopped Working

My blower motor in my Jetta recently stopped working. When I turn on the blower it works for 10 seconds or so then slows down and dies. Is this a blower motor or resistor problem?

View 1 Replies

Sonata NF (2006-10) :: Blower Motor Not Working - Switch Is Not Getting Power?

I have a problem with my 09 Sonata. Blower motor does not work at all, on any setting. I thinks it's not getting any power. When I turn the blower on, on the dash, little red light does not come on on the switch. I think the switch itself that controls the speed and power to the blower is not getting any power.

I checked fuses that control the blower and they are fine (I looked up fuse location online).

View 2 Replies

Accent MC (2006-11) :: 2008 - Blower Motor Stopped Working

Got a 2008 Hyundai Accent. Yesterday, the blower motor just stopped working. I had just started it up, the heater came on for about five seconds. There was no noise, no funny smell, nobody had done anything to it. It just stopped. I checked the ac fuse and it looked fine. I looked in the fuse box under the hood, and I'd like to check the fusible link for the blower motor to see if it has a problem. Is this something I could do and how? Also is there anything else I can do to diagnose the cause of the problem?

View 2 Replies

Toyota - Corolla :: 2007 - A/C Blower Motor Stopped Working?

The air conditioning blower motor stopped working this past summer (worst timing ever). I took it out, put it back in, and it worked again for a day before dying for good. So, I ordered a new one and replaced it. The replacement was working fine for about 5 months, but it then began exhibiting the same problem as the original: it wouldn't come on until after I'd been driving for a while. The new unit never made any unusual noises while running (the old one got noisy just before I replaced it), but now it isn't coming on at all. I find it hard to believe that the replacement blower motor has failed after only 5 months. What else should I check?

View 5 Replies

Touareg :: 2005 - AC Stopped Working / Blower Motor Frozen Up

My air conditioning has stopped working and the dealer tells me the blower motor has frozen up. This car only has 73k on it. Is this common to the 2005 Touareg or ?????

View 3 Replies

Ford F-150 - 1997-2003 :: Blower Motor / Blinkers Not Working

My 99 f150 blower motor and blinkers slowly but surely went out on me. The hazards still work. I changed the flasher relay and the relay for the blower motor, and nothing. I've checked all the fuses, and checked for wire issues and nothing.

View 4 Replies

Passat (B6) :: Blower Motor / Heated Seats And Rear Wipers Not Working

My sister was driving her Passat the other day and the AC stoped blowing, the cigar lighter quit working, heated seats & rear wipers dont work. I checked the fuses and they look good.

View 6 Replies

Ford A/C :: 2003 F150 - Blower Motor Stopped Working All Of A Sudden

I've read quite a few threads on this subject and came across the resistor, fuses, and relays. I have some fundamental testing procedure questions.

1. To test the resistor, it says to back probe the brown/orange wire to check for voltage. So I'm assuming I would hook up my positive lead, here?

Do I really need to hook up the black lead all the way to the negative terminal on the battery? Just with a long extension? Or is there somewhere else I can hook the black lead to? (I know, how dumb!)

2. I downloaded owners manual, but I can't seem to find a fuse or relay specifically for the blower, so what fuse and what relay is it?

3. In the Haynes manual, it says locate the blower motor relay, in the relay box under the center dash panel, where the hell is that?

4. Do I need to remove the glove box to access the resistor and blower hosting.

5. Anything else I should know?

View 8 Replies

Ford A/C :: 2003 E350 - Front Heater / AC Blower Motor Isn't Working

Recently bought a 2003 E350. The front heater/ac blower motor isn't working. I found the control switch melted and bought a new switch. Before installing it, I need to do some diagnostics. I checked the blower with a couple of jumpers ant it turns and blows. I think that leaves the blower motor resistor. Where it is on a 2003 E350? I also need to check the relay. I have a power distribution box at the front left under the hood. Is the relay there? The box is not labeled like my GM products. Which is the blower motor relay? Finally, which fuse controls the blower motor? I read it might be a 40 amp fuse. If so, that might narrow it down.

View 6 Replies